Benchtop Pulse Vacuum Autoclave, Class B Scitek Global
The ST-B60/80PV series is a type B sterilizer that
uses steam as a medium. It achieves sterilization of items by repeatedly
extracting vacuum and filling the sterilization chamber with steam to create a
certain level of vacuum before introducing saturated steam, reaching the set
pressure and temperature to achieve the purpose of sterilization. It is
suitable for use in medical and health care departments such as stomatology,
ophthalmology, operating rooms, supply rooms, and analysis rooms for
sterilizing solid instruments, type A hollow instruments, implantable
instruments, dressings and fabrics, rubber catheters, and liquid items.
The non-liquid program is suitable for the
sterilization of surgical instruments, solid bare instruments, packaged
instruments, rubber loads, etc. The liquid program is suitable for the
sterilization of liquids such as water and culture media.
Features
ü
Process control
The whole process of preheating, replacement, heating, sterilization, exhaust
and vacuum drying is automatically operated; it uses steam as the medium,
adopts an efficient vacuum pumping system, and repeatedly pumps vacuum to
achieve the effect of sterilization and drying.
ü
Multi-point Temperature Control Technology
Non-sealed liquid programs use mobile temperature sensors to measure
tempera-ture, which can detect the internal temperature of the liquid in real
time, making the internal temperature of the liquid more intuitive and clear.
ü
Insulation Function
The insulation function can be set as needed to achieve liquid culture medium
sterilization, culture medium dissolution-insulation function.
ü
Safety Function
With over-temperature automatic protection device, anti-dry burning protection
device, over-pressure automatic release device, over-current protection
device, electronic circuit safety device
ü
Self-calibration Function
It has a complete background self-calibration system to realize the calibration
of system parameters such as pressure and temperature. Without
disassembling the instrument, the authorized tool can be used for on-site
adjustment.
ü
Independently Installed Pressure Sensors
An independent pressure transmitter is installed in each of the inner chamber
and evaporator to ensure that the equipment pressure is within the safe
control range
ü
Water Injection and Drainage Method
Automatic water injection, automatic drainage
Specification
|
Parameter
|
ST-B60PV
|
ST-B80PV
|
|
Capacity
|
60L
|
80L
|
|
Chamber Size (mm)
|
φ391 x 521
|
φ391 x 671
|
|
Working Temperature
|
121℃ / 134℃
|
121℃ / 134℃
|
|
Sterilization Temperature
|
150℃
|
150℃
|
|
Designed Pressure
|
-0.1 / 0.3 Mpa
|
-0.1 / 0.3 Mpa
|
|
Chamber Material
|
SUS304 Stainless Steel
|
SUS304 Stainless Steel
|
|
Water Tank Capacity
|
14L
|
14L
|
|
Power Consumption
|
5.8 kW
|
6.2 kW
|
|
Power Supply
|
220V/110V, 50/60Hz
|
220V/110V, 50/60Hz
|
|
Operational Noise
|
≤ 65 dB
|
≤ 65 dB
|
|
External Size (WxDxH)
|
990 x 804 x 675 mm
|
1140 x 805 x 675 mm
|
|
Package Size (WxDxH)
|
1130 x 960 x 940 mm
|
1330 x 960 x 940 mm
|
|
Net / Gross Weight
|
175 kg / 215 kg
|