CO2 Incubator AP Series Scitek Global
Features
1. Natural evaporation for humidification to ensure the chamber can
maintain good humidity.
2. Microcomputer control, large LCD screen, accurate and easy for
operation.
3. Imported infrared sensor and gold-plated probes to ensure
accuracy, the life time of sensor is up to 15 years.
4. Adopting PID control technology, the CO2 concentration can be
freely set within range of 0 to 20%, alarm for over concentration and
concentration rise too slow.
5. Water jacket and air jacket structure are available, polished
304 stainless-steel chamber with air duct. Equipped with fan for forced
convection, ensuring good temperature uniformity and the balance of CO2
concentration inside.
6. When door opened, the fan will automatically turned off (the CO2
will be turned off intake valve at same time) and heating will be stopped to
reduce the pollution caused by the entry of air.
7. PID microprocessor is used to control temperature, meanwhile,
the temperature of box ,water and door are separately controlled by three
probes to ensure high accuracy. (Air jacket is equipped with two probes to
control door temperature and main body temperature.)
8. CO2 incubator's digital display for setting parameters, each
working state has LED indication.
9. Alarm function for over-heating, lack of water, unaspirated,
ensuring the safe operation of the equipment.
10. The CO2 incubator is equipped with sterile air filtration
devices and UV light system to reduce pollution.
Specification
| Model | ICB-C40AP | ICB-C80AP | ICB-C150AP | ICB-C190AP | ICB-C240AP | ICB-C500AP |
|---|
| Capacity(L) | 40 | 80 | 150 | 190 | 240 | 500 |
| Internal Size (W×D×H)(mm) | 400×286×350 | 400×450×500 | 480×530×610 | 520×530×690 | 600×630×670 | 700x650x1100 |
| External Size (W×D×H)(mm) | 590×440×576 | 590×687×790 | 670×767×880 | 708×710×1030 | 788×837×940 | 880x860x1500 |
| Heating Method | Air jacket (casing microcomputer PID control) |
| Temperature Control Range | RT+5~55℃ |
| Working Environment Temperature | +5~30℃ |
| Temperature Fluctuation | ±0 1℃ |
| CO2 Control Range | 0~20% |
| CO2 Control Accuracy | ±0.1% (infrared sensor) |
| CO2 Recovery Time | (Recovery to 5% in 30 seconds)≤ 3 minutes |
| Temperature Recovery | (Return to 37℃ in 30 seconds)≤ 8 minutes |
| Relative Humidity | Natural evaporation ≥ 90% (can be equipped with relative humidity digital display) |
| 90 ℃ High Temperature Moist Heat Sterilization | Yes |
| Load Carrier (Standard) | 2 pcs | 3pcs |
| Power Supply | AC 220/110V, 50/60Hz |
| Input Power | 350W | 500W | 750W | 750W | 950W | 1450W |
| N.W./G.W. (kg) | 50/70 | 64/90 | 85/112 | 90/134 | 95/148 | 195/320 |
| Shipping Size (WxDxH)(mm) | 650×710×740 | 750×710×960 | 840×790×1070 | 830x840x1250 | 960×900×1160 | 1020×1000×1610 |
| Optional | RS485 Connector: Easy to download and save all the data via RS485 into computer, and identify problems in time. |
| Humidity display system. |
| Embedded printer |