CO2 Incubator ICB-CA Series Scitek Global
Six-sided heating
gas jacket heating system
1. Six-sided heating ensures uniform temperature distribution with
a uniformity of up to ±0.4°C.
2. Built-in fan gently blows air so that it is evenly distributed
in the chamber, ensuring a consistent culture environment.
3. Removable drawer-style shelves can be flexibly combined, and the
independent humidification water tray can be taken out or put in according to
needs.
4. Stainless steel shelves and brackets are durable and can be
removed without tools.
5. Stainless steel inner cavity with large rounded corners for easy
cleaning.
90°C high
temperature moist heat sterilization
1. 90°C high temperature and moist heat sterilization function, no
need to disassemble parts separately.
2. The 90℃ high temperature and wet heat sterilization system can
effectively eliminate the microbial contamination caused by bacteria, molds,
mycoplasma and other microorganisms on the surface of the inner cavity to cell
culture, providing users with a safe experimental environment.
CO2 Incubator Technical Feature:
IR
sensors are designed for precise monitoring
1. Infrared (IR) CO, sensor, stable monitoring of the culture
environment, effectively avoiding the measurement deviation caused by frequent
opening and closing of the door.
2. Suitable for remote monitoring or when the incubator needs to be
opened frequently.
Active
Airflow Technology
1. The CO2 incubator is equipped with fan-assisted air circulation
to achieve rapid recovery. This airflow pattern is specially designed to evenly
distribute temperature, gas exchange and humidity.
2. The incubator’s built-in fan ensures that all cells, regardless
of where they are placed, have the same culture environment conditions and will
not lose water excessively when the incubator is turned on.
7-inch
LCD touch screen
1. Intuitive control and easy operation, can display real-time
operation curve, historical operation curve.
2. The installation position on the upper part of the outer door is
convenient and easy to operate, and the capacitive touch screen is sensitive
and has a good control experience.
3. Voice and visual alarm, screen menu prompts, alarm records can
be queried.
Unique
shelf design
The
chassis shelf design has a large evaporation area and the humidity recovers
quickly after closing the door. It ensures a high humidity environment in the
incubator. Under normal room temperature conditions, even when high humidity is
generated, it is still difficult to generate condensation water above the
cabin. It provides the greatest protection for cell and tissue culture and
avoids the formation of dangerous condensation.
Historical
data can be viewed, monitored, and exported
1. Historical data can be viewed, monitored and exported through
the USB interface.
2. Historical data cannot be changed, and the original data can be
traced back effectively.
Specification
| Model | ICB-C160A | ICB-C195A | ICB-C185W |
|---|
| Capacity(L) | 160 | 195 | 185 |
| Internal Size (W×D×H)(mm) | 480x480x698
| 500x500x780
| 490x490x770
|
| External Size (W×D×H)(mm) | 675x695x975
| 695x715x1060
| 685x705x1030 |
| Heating method | Air jacket | Water jacket |
| Temperature control range | RT+5-60℃ |
| Temperature fluctuation (℃) | ≤±0.2℃
|
| Temperature Uniformity (℃) | ≤±0.4℃(37℃) |
| CO2 control range | 0~20% |
| CO2 control accuracy | ±0.1% |
| CO2 recovery time | (Recovery to 5% in 60 seconds)≤ 6 minutes |
| Temperature recovery | (Return to 37℃ in 60 seconds)≤ 5 minutes |
| Relative humidity | ≤90%RH±3% |
| 90 ℃ high temperature moist heat sterilization | Yes |
| Load carrier (standard) | 3pcs |
| Power Supply | AC220V 50/60Hz |
| Input power | 800W | 1150W | 1100W |
| Shipping Size (W×D×H)(mm) | 880x860x1200 | 890x880x1250 | 880x860x1200 |
| G.W.(KG) | 121 | 133 | 158 |